- Modell Nr.: s-100-24
- Ausgabetyp : Single
- Garantie : 1 Jahr
- Ausgangsleistung : 51 - 100W
- Eingangsspannung : 110-220V
- Connection Mode : Series Switching Power Supply
- Startmodus : Self-excited Switching Power Supply
- Spannungsregelung : Frequency Modulation Type
- Stromversorgungssystem : Terminal Power Distribution Equipment
- Bescheinigung : CE
- Trademark: Minsen
- Packing: Standard Exporting Cartons
- Standard: 199*98*38mm
- Origin: Zhejiang China
- HS Code: 8504401990
- Production Capacity: 50000PCS/Month
Modelle Spg.Versorgungsteil der Schaltung 100W des 100W Spg.Versorgungsteils
Modell, Ausgangsleistungsstrom-spannungs
S-100-5, 100W 5V 20A
S-100-7.5, 100W 7.5V 13.5A
S-100-10, 100W 10V 10A
S-100-12, 100W 12V 8.5A
S-100-15, 100W 15V 6.7A
S-100-18, 100W 18V 5.6A
S-100-24, 100W 24V 4.5A
S-100-27, 100W 27V 3.7A
S-100-48, 100W 48V 2A
Eingangsspannungsuniversaleingangsspannung: 110/220VAC± 20% vorgewählt durch Schalter
Spezifikation des Spg.Versorgungsteils der Schaltung 100W
1. Niedriger Preis und hohe Zuverlässigkeit
2.105 ausgegebener Kondensator
3. Wechselstrom-zugeführte Energie verwendbar für die Welt
4. Hohe Leistungsfähigkeit und niedrige Betriebstemperatur
5. Strom Weich-beginnen kann die Wechselstrom-Eingangsauswirkung effektiv verringern
6. Mit Kurzschluss- und Überlastungsschutz
7. Kompakte Größe, leicht
full-load brennender Test 8.100%
9. Angebracht mit Entstörfilter, minimale Welle
MODEL | S-100-5 | S-100-7.5 | S-100-10 | S-100-12 | S-100-15 | S-100-18 | S-100-24 | S-100-27 | S-100-48 | |
DC VOLTAGE | 5V | 7.5V | 10V | 12V | 15V | 18V | 24V | 27V | 48V | |
RATED CURRENT | 20A | 13.6A | 10A | 8.5A | 6.7A | 5.6A | 4.5A | 3.7A | 2A | |
CURRENT RANGE | 0 ~ 20A | 0 ~ 13.6A | 0 ~ 10A | 0 ~ 8.5A | 0 ~ 6.7A | 0 ~ 5.6A | 0 ~ 4.5A | 0 ~ 3.7A | 0 ~ 2A | |
RATED POWER | 100W | 102W | 100W | 102W | 100.5W | 100.8W | 108W | 99.9W | 96W | |
RIPPLE & NOISE (max. ) | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
VOLTAGE ADJ. RANGE | 4.75 ~ 5.5V | 6.75 ~ 8.25V | 9 ~ 11V | 10.8 ~ 13.2V | 13.5 ~ 16.5V | 16.2 ~ 19.8V | 21.6 ~ 26.4V | 24.4 ~ 29.7V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE | ± 2.0% | ± 1.0% | ± 1.0% | ± 1.0% | ± 1.0% | ± 1.0% | ± 1.0% | ± 1.0% | ± 1.0% | |
LINE REGULATION | ± 0.5% | ± 0.5% | ± 0.3% | ± 0.3% | ± 0.3% | ± 0.3% | ± 0.2% | ± 0.2% | ± 0.2% | |
LOAD REGULATION | ± 0.5% | ± 0.5% | ± 0.3% | ± 0.3% | ± 0.3% | ± 0.3% | ± 0.2% | ± 0.2% | ± 0.2% | |
SETUP, RISE, HOLD TIME | 200ms, 80ms, 20ms at full load | |||||||||
VOLTAGE RANGE | 85 ~ 132VAC/180 ~ 264VAC selected by switch 255 ~ 370VDC | |||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
EFFICIENCY (Typ. ) | 78% | 80% | 80% | 81% | 81% | 82% | 84% | 84% | 84% | |
AC CURRENT | 2.4A/115VAC 1.2A/230VAC | |||||||||
INRUSH CURRENT (max. ) | COLD START 30A/115VAC 60A/230VAC | |||||||||
LEAKAGE CURRENT | < 1mA / 240VAC | |||||||||
OVERLOAD | 105 ~ 150% rated output power (150 ~ 200% rated output power for S-100-7.5 only) | |||||||||
Protection type: Shut down o/p voltage, re-power on to recover. | ||||||||||
WORKING TEMP. | -10 ~ +60º C | |||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -20 ~ +85º C, 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | ± 0.03%/º C (0 ~ 50º C) | |||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min. /1cycle, 60min. each along X, Y, Z axes | |||||||||
SAFETY STANDARDS | Design refer to UL1012 | |||||||||
WITHSTAND VOLTAGE | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC | |||||||||
EMI CONDUCTION & RADIATION | Design refer to FCC Part15 J Conduction Class B | |||||||||
MTBF | 322.4K hrs min. MIL-HDBK-217F (25º C) | |||||||||
DIMENSION | 199*98*38mm (L*W*H) | |||||||||
PACKING | 0.578Kg; 30pcs/19.24Kg/0.0250CMB |